SYMPTOMS
After Microsoft MS-DOS version 5.0 or later as been installed on a Vendex
Headstart XT computer, the date will not display correctly. When the
correct date is set, this system continues to display the incorrect year.
CAUSE
A file called ST.COM is responsible for maintaining the correct date and
time on the Vendex Headstart XT computer. ST.COM was written specifically
for this computer for use with MS-DOS version 3.2 ONLY. This file will not
maintain the correct year under any other version of MS-DOS. However, the
time, month, and day settings will be correctly maintained by ST.COM.
According to Philips technical support, the only workaround is to purchase
a compatible 8-bit clock card to maintain proper settings.
The products included here are manufactured by vendors independent of
Microsoft; we make no warranty, implied or otherwise, regarding these
products' performance or reliability.